bora PL 540 Manual De Instrucciones página 17

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57
Installation of the cooker extractor
Before you start with the installation, make sure the
countertop measurements are correct. You can view
the precise component dimensions on page 16 and 17
of this User Manual.
The appliance may only be connected to the electric
circuit by a certified electrician in accordance with
regional provisions. The same applies to the ventilation
ducts.
The installer is responsible for proper appliance
functionality at the installation site.
The extractor can be used in extraction or recirculation
mode. The ventilation ducts are compatible with
COMPAIR Flow 150 by Naber.
The extracted air should be transported outside
through outlet ducts. The extracted air must not be
transported to operating chimney flues or combustion
gas ducts. Where the extracted air is to flow through
non-operational
chimneys,
consultation with the responsible chimney sweeper
first.
Iftheextractorisused in combinationwith a gas,
charcoal,
oilorwood-burningoven,
provideforsufficientventilation.
An under-pressureof 4 Pascal (= 0.04 mbar) must
not
beexceeded!
ensuresufficientcombustionairflowthrough
doorsandwindowsor an airsupplydevice.
you
must
have
a
you
must
Toremainbelowthislimit,
open
The minimum diameter for outlet ducts is 150 mm. It is
recommended to use outlet ducts larger than 150 mm.
The following air ducting guidelines must be followed:
Keep air passages as short as possible
-
Avoid acute angles, rather installing ducts in
-
gentle curves
Never use ducts with diameters smaller than
-
150 mm
-
Avoid curves and angles 500 mm before and
after the fan components
If the extractor is used in recirculation mode, it is
recommended to fit the BORA charcoal filter.
Where the extractor is installed in combination with a
BORA cooktop, the extraction unit can be placed to the
left or right of the cooktop.
If the extractor is installed in combination with two
cooktops, then it is to be placed between the two
cooktops. The same applies to the installation of three
cooktops with two extractors (see combination options
on p. 22).
Installation examples:
Adjacent installation of
3 cooktops /
2 extractor units
17
GB

Publicidad

Tabla de contenido
loading

Tabla de contenido