Xamp3K
3 MAIN CONTROLS AND CONNECTIONS
3.1 The front panel
Fig. 1. Front panel view
A) Power Switch – On-Off switch with Led
B) Volume Controls – Potentiometers to independently control the output level for
each way.
C) Cooling outs – Forced air output for temperature regulation.
D) VU-Meters – Independent output signal indicators, with Leds for different relative
levels: -36dB, -24dB & -12dB.
E) Limiter – Led indicating the operation start of the anti-clipping or limiter systems.
F) Protection – Led indicating the operation of any of the protection system of one
or both channels. At power up normally it will turn ON momentarily. If it does not
turn OFF, indicates a problem of malfunction of the amplifier.
G) Panel screws – Detach (no tools needed) to access the internal panel
3.2 The internal front panel
Detach the front panel using the two screws (G) to access this panel.
Fig. 2. Internal front panel
H) Limiter adjust – Easy adjustment for the limiter threshold of each output. For
more information see Section "Limiter Adjustment".
5
May 2016
Amate Audio