3.5 End of operation

Turn the red start/stop button (1) to position 0. Disconnect the water supply and activate the spray handle.
Detach the high pressure hose. Never jerk the cable to disconnect the plug from socket.

3.6 Transport directions

3.7 Storage

Prior to storing the machine should be completely emptied of water as follows:
1. Detach the inlet hose and the high pressure hose and empty them of water.
2. Start the machine and let it run until the water has run out of the pump system. »The machine will auto-
matically stop«.
If the room is not frost-free the machine should be protected as follows:
1. Detach spray lance and empty the machine by allowing it to run without water.
2. Place the inlet hose in a container with an anti-freeze.
3. Draw in the anti-freeze by activating the spray handle. Activate the spray handle 2-3 times while placing
it above the container with anti-freeze so that the anti-freeze can circulate.
4. Remove the inlet hose from the container, activate the spray handle and the rest of the anti-freeze is
lead back to the container.
NB! By repeated use the anti-freeze will be diluted with water and thus loose its effect.
Operating instructions
Turn to position 0
1
Never detach the high pressue hose while
the machine is in operation = Position 1.
Always secure the machine during trans-
port. The brake on the castor wheel (1)
should be applied during transport.
1
Frost-free room or anti-freeze solution
The transport handel of the machine can
be folded up by loosening the two miled
nuts (17).