Error
E411
Exceeding of the maximum engine
temperature
completes the cycle in progress
E412
Handle overheating
E416
Engine temperature sensor faulty
E417
DSP board temperature sensor faulty The temperature sensor on the DSP board registers an abnormal
E418
No communication with the torque
transducer
>E500
E2PROM access error
E501
Error of data size sent to the EEPROM
E502
Reading error of CRC on "Identification - Tool - Calibration" parameters
E503
Reading error of CRC on "Code - Station - Sequence - Cycle" parameters
E504
Reading error of CRC on "Maintenance" parameters
E511
Reading error of "Identification - Tool - Calibration" parameters
E512
Reading error of "Code - Station - Sequence - Cycle" parameter
E513
Reading error of "Maintenance" parameters
E514
Writing error of STATION parameter
E515
Writing error of ACCESS CODE parameter
E516
Writing error of CYCLE parameter
E517
Writing error of SEQUENCE parameter
E519
Writing error of the error table
E521
Writing error of the cycle manually set up
E522
Writing error of target torque when learning
E524
Software version
E525
Writing error of CALIBRATION parameters
E526
Writing error of the torque coefficient
E527
Writing error of linearity table
E528
Writing error of motor offset coefficients
E529
Writing error of CRC on "Identification - Tool - Calibration" parameters.
E530
Writing error of CRC on "Code - Station - Sequence - Cycle" parameters
E531
Writing error of CRC on "Maintenance" parameters
E532
Writing error of the tool option
E533
Writing error of the tool type
Description
Wait for the tool to cool down. The tool can tighten again when the
(60°C);
the
tool
temperature is lower than 55°C. This means that the tool tightening rate
is too big or that the ambient temperature is higher than the usual
temperature. Make sure that the tightening rate is adapted to the
maximum tightening rate recommended by the manufacturer. Make sure
that the tightening parameters (run down torque, speed) have been
optimised. Perform a learning for the assembly.
Never close up ventilation inlet, make sure the fan is in operation (a faint
noise is audible). The tool can tighten again when the temperature is
back to normal.
The temperature sensor on the hall board registers an abnormal
temperature (T<-10°C ; T>110°C). The tool has stopped. Check the hall
board connection / change the hall board / contact our customer service.
temperature (T<-10°C ; T>110°C). The tool has stopped. Change the
DSP board / contact our customer service.
This error appears when the communication between the torque
transducer and the DSP is interrupted for any reason. It may be a flat
cable fault, a disconnection of the flat cable or a torque transducer
electronic fault.
The tool data are no longer available (E2PROM access faulty, data
partially or totally modified or lost). Contact our customer service.
EAP/EDP
Checking/Actions