4.6
Measuring Radius (X) and Length (Z)
Figure 10: Control device Smart Pro III
Move the measuring carriage until the cutting edge appears in the display
Define the coordinates according to the control device
Read the values for X and Z on the display
4.7
Completing the Measurement
Remove the measuring carriage from the working area
Remove the tool from the tool holder
Switch off the main switch once you have finished measuring
4.8
Saving the Adapter
Calibrate the display instruments (=save the adapter) for the X and Z Axis using the
known measured variables of the setting mandrel
Measure X and Z of the setting mandrel
Save the values according to the manual for the control device in a suitable adapter
data record. This adapter applies to all measurements using the current tool holder.
Observe the manual for the control device
Seite 20
Kelch GmbH • Werkstraße 30 • D-71384 Weinstadt-Endersbach • Tel. (+49)7151 20522 0 • Fax (+49)7151 20522 11 • info@kelchgmbh.de
KENOVA set Line V224 Kelch GmbH 2013
4 Operation