Maintenance and cleaning

W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
• Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
• Isolate the device (disconnect from the power supply) before carrying out any work on it.
Cleaning the air filter
How to proceed:
 D
1. Remove the filter holder from the top section of the housing with the aid of a screwdriver.
2. Remove and shake out the filter fleece or replace if necessary.
3. Push the filter fleece into the filter holder.
– Pay attention to the O ring as it holds the filter holder in the housing.
4. Reassemble the unit in the reverse order.
Replacing the membrane
N O T E
Do not operate the unit with a defective membrane.
• Please contact your specialist dealer if you do not wish to undertake the replacement yourself.
Opening the housing
How to proceed:
 E
• Undo the screws on the bottom section of the housing and remove the top section of the housing from the bottom
section.
Removing the pump
How to proceed:
 F
1. Remove the membrane.
2. Use a screwdriver to lever the membrane clip out of its guide socket.
3. Use a screwdriver to lever the pump casing out of its guide socket.
– Use the guide socket of the membrane clip as a pivot point for the screwdriver.
– Keep the cover with rubber mat.
Replacing the membrane
How to proceed:
 G
1. Remove the nut and screw, fit a new membrane and screw on with the membrane clip.
– Secure the nut using varnish.
2. Fit the membrane over the rim fitting of the pump.