ENGLISH
OVERHEAD RIGGING
Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
Make sure the area below the installation place is free from unwanted
persons during rigging, de-rigging and servicing.
Locate the fixture in a well ventilated spot, far away from any flammable
materials and/or liquids. The fixture must be fixed at least 50cm from
surrounding walls.
The device should be installed out of reach of people and outside areas
where persons may walk by or be seated.
Before rigging make sure that the installation area can hold a minimum
point load of 10times the device's weight.
Always use a certified safety cable (number 3 on the picture) that can hold
12 times the weight of the device when installing the unit. This secondary
safety attachment should be installed in a way that no part of the
installation can drop more than 20cm if the main attachment fails.
The device should be well fixed; a free-swinging mounting is dangerous
and may not be considered!
Don't cover any ventilation openings as this may result in overheating.
The operator has to make sure that the safety-relating and machine-
technical installations are approved by an expert before using them for the
first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
HOW TO SET UP THE UNIT
FRONT + BACK PANEL:
1. DISPLAY: shows the various menus and the selected functions.
2. BUTTONS:
MODE-button: used to enter and leave the setup menu.
UP/DOWN-buttons: browse the setup menu up/down and change the value of parameters.
ENTER-button: confirm your actions.
3. IR REMOTE RECEIVER: receives the infrared instructions from the IR-remote while the unit is used in
standalone or master/slave mode.
4. DMX IN/OUTPUTS: used for DMX512 linking, use balanced signal cables with 3pin XLR-connectors.
5. USB 5Vdc output: this is NOT a data connector, it's only a 5Vdc/350mA output that can be used to
supply power to future accessories.
6. MAINS INPUT/OUTPUT: with IEC socket and integrated fuse holder, connect the supplied mains cable
here. You can use a special IEC power cable to connect the output with the mains input of the next unit
for easier linking up to 10A.
Hint: Please check our website for special cable assemblies that contain both power and balanced
signal (XLR 3pin) in one cable. Different lengths are available: 1.3m, 3m, 5m and 10m, very convenient!
7. SAFETY EYE: fix an optional safety cable here when the unit it installed above the crowd.
8. U-BRACKET: used when the projector is fixed in truss using a standard ALU-clamp.
JB SYSTEMS
®
3/59
USER MANUAL
DYNASPOT