ELECTRICAL
Refer to all safety instructions before using unit. Observe extension
cord safety instructions
if necessary. Always move the On/Off
switch (A) to the OFF position before removing the plug from the
outlet.
TRANSPORTING
When transporting the compressor in a vehicle, trailer, etc., ensure
that the tank is drained and the unit is secured. Use care when driv-
ing to avoid tipping the unit over in the vehicle. Damage can occur to
the compressor or surrounding items if the compressor is tipped.
MOVING
When moving the compressor, grasp the handle and carry the com-
pressor as close to the body as possible.
_, WARNING: Risk of unsafe operation. Ensure proper footing and
use caution when carrying compressor to avoid a loss of balance.
PREPARATION
FOR
USE
Pre-Start
Checklist
(Fig.
1)
1. Ensure the On/Off switch (A) is in the OFF position.
2. Plug the power cord into the correct branch circuit receptacle.
See Voltage and Circuit Protection
under Installation.
3. Ensure air tank is drained,
see Draining
Air Tank under
Maintenance.
4. Ensure the drain valve (H) is closed.
5. Ensure safety valve (G) is functioning properly, see Checking
Safety Valve under Maintenance.
6. Check pump oil level, see Compressor
Pump Oil under
Maintenance.
CAUTION: Do not operate without oil or with inadequate oil. DEWALT
is not responsible for compressor failure caused by inadequate oil.
7. Turn regulator knob (D) counterclockwise until fully closed. Ensure
regulated pressure gauge reads 0 PSI (0 kPa).
8. Attach hose and accessories.
_k WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
9. Ensure all covers and labels are in place, legible (for labels) and
securely mounted. Do not use compressor until all items have
been verified.
• , WARNING: Risk of bursting. Too much air pressure
causes a
hazardous
risk of bursting. Check the manufacturer's
maximum
pressure rating for air tools and accessories.
The regulator outlet
pressure must never exceed the maximum pressure rating.
Initial
Set.up
(Fig.
1)
WARNING: Do not operate this unit until you read and understand
this instruction
manual
for safety, operation
and maintenance
instructions.
BREAK-IN PROCEDURE
_k WARNING: Serious damage may result if the following break-in
instructions are not closely followed.
This procedure is required before the air compressor
is put into
service for the first time and when the check valve or a compressor
pump/motor has been replaced.
1. Ensure the On/Off switch (A) is in the OFF position.
NOTE: If hose is not connected to Quick Connect body, pull coupler
back until it clicks to prevent air from escaping through the quick
connect.
2. Plug the power cord into the correct branch circuit receptacle. See
Voltage and Circuit Protection
under Installation.