Sears Kenmore Pro 79079523600 Manual De Instrucciones página 5

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Direct
EJectrical
Connection
to the
Circuit
Breaker,
Fuse
Box or Junction
Box
If the appliance is connected directly to the circuit breaker,
fuse box or junction box, use flexible, armored or non
metallic sheathed copper cable (with grounding wire).
Supply a U.L listed strain-relief at each end of the cable. At
the appliance end, the cable goes through the Direct
Connection Hole (see Figure 4) on the Cord Mounting
Plate. Wire sizes (copper wire only) and connections must
conform to the rating of the appliance.
You may not ground
the oven
through
the neutral
(white)
wire
if oven
is used
in
a new
branch
circuit
instaJlation
(1996
NEC), mobiJe
home,
recreational
vehicle,
or where
local codes
do
not permit
grounding
through
the neutral
(white)
wire.
When
grounding
through
the neutral
(white)
wire
is prohibited,
you
must
use a 4-wire
power
supply
cable.
See Figure
6. Failure
to heed
this
warning
may resuJt in eJectrocution
or other
serious
personaJ
injury.
Where local codes permit connecting
the appJiance
cable ground
wire to the power suppJy cable
neutral
(white)
wire (see Figure 5).
I. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box:
Connect appliance and power supply cable wires as
shown in figure 5.
Cable from Power Supply
White Wire
(Neutral)
RedWires
Wires
1
Box
White Wire
(Neutral)
Ground Wire
U.L-Listed
(Bare or Green Wire)
Conduit Connector
(or CSA listed)
Cable from appliance
Figure 5
3-WIRE GROUNDED JUNCTION BOX
improper
connection
of aluminum
house
wiring
to copper
leads can result
in a short
circuit
or fire.
Use onJy connectors
designed
for
joining
copper
to aluminum,
and follow
the
manufacturer's
recommended
procedure
closely.
if oven is used in a new branch circuit
installation
(1996 NEC), mobile home, recreational
vehicle, or
where
local codes DO NOT permit connecting
the
appliance
cabJe ground
wire to the power
supply
cable neutral
(white)
wire you must use a 4 wire
power
supply cable (see figure
6):
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box:
Connect appliance and power supply cable wires as
shown in figure 6.
Ground
Wire
Cable from Power Supply
White Wire
Ground Wire
(Bare or
Green Wire)
_White
Wire
Junction Box
U.L-Listed
Conduit Connector
(or CSA listed)
Cable from appliance
Figure 6
4-WIRE GROUNDED JUNCTION BOX
DO NOT ground to a gas supply pipe. DO NOT connect
to electrical power supply until appliance is permanently
grounded. Connect the ground wire before turning on
the power (Figure 6).
NOTE TO ELECTRICIAN: The armored cable leads
supplied with the appliance are UL-recognized for
connection to larger gauge household wiring. The
insulation of the leads is rated at temperatures
much
higher than temperature rating of household wiring. The
current carrying capacity of the conductor is governed by
the temperature rating of the insulation around the wire,
rather than the wire gauge alone.