30" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
OBSERVE ALL GOVERNING CODES AND ORDINANCES.
If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
FOR YOUR SAFETY:
— Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
•
Do not try to light any appliance.
•
Do not touch any electrical switch; do not use any phone in your building.
•
Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
•
If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
(75.9 cm Min.)
If there is a wall:
See note
7" Min.
(17.78 cm Min cm Min.)
Left side
G
F
Grounded
Wall Outlet or
junction box
location
Do not pinch the power supply cord between the range
and the wall.
Do not seal the range to the side cabinets.
A. HEIGHT
B. WIDTH
41 7/8"
29 7/8"
(106.4 cm)
(75.9 cm)
Note: Wiring diagram for this model is enclosed in this booklet (see page 24).
Printed in Canada
(Model with Electric Oven and Gas Cooktop)
29 7/8" Min.
18" Min.
(45.7 cm Min.)
If there is a wall:
7" Min.
(17.78 cm Min.)
Right side
24" Min.
(61 cm Min.)
24 1/2" Max.
(62.2 cm Max.)
C. DEPTH TO
FRONT OF RANGE
26 1/2"
(67.3 cm)
(91.4 cm ± 0.3 cm)
13" Min.
(33 cm Min.)
D
NOTE: 24" (61 cm) minimum clearance between the
cooktop and the bottom of the cabinet when the bottom
of wood or metal cabinet is protected by not less than
1/4" (0.64 cm) flame retardant millboard covered with
not less than No. 28 MSG sheet metal, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum, or 0.020"
(0.5 mm) copper.
30" (76.2 cm) minimum clearance when the cabinet is
unprotected.
D. HEIGHT OF
E. DEPTH WITH
COOKTOP
DOOR OPEN
36" ± 1/8"
45 1/2"
(115.6 cm)
1
Note: For
appliances
installed in
the state of
Massachusetts
see page 3.
C
B
E
F. HEIGHT OF
COUNTERTOP
CUTOUT WIDTH
36" (91.4 cm) Standard
35 3/8" (90 cm) Min.
P/N 318201780 (1302) Rev. B
English - pages 1-11; Español - páginas 12-23
Wiring Diagram - page 24
A
G. MINIMUM
30 1/8"
(76.5 cm)