Replacement parts and accessories
If your dryer requires replacement
parts or accessories, contact the dealer where you purchased your dryer or the
SAMSUNG customer care center at 1-800-SAMSUNG (726-7864).
Installation
For the proper
installation,
we recommend
that you hire a qualified
installer.
1.
Move your dryer to an appropriate
location for the installation.
Consider installing the dryer and washer side-by-side, to allow access
to the gas, electrical, and exhaust connections.
Place two of the carton
cushion-tops
on the floor.Tip
your dryer on its side so it lies across
both cushion-tops.
2,
Set your dryer back in an upright position.
3,
To ensure that the dryer provides the optimal drying performance,
it
must be level. To minimize vibrations, noise, and unwanted
movement,
the floor must be a perfectly
level, solid surface.
To set the dryer to the same height as the washer, fully retract the
leveling
feet CA) by turning them counterclockwise,
then loosen the
legs by turning them clockwise.
Adjust the leveling feet only as much as necessary to level the
dryer. Extending
the leveling feet more than necessary can
cause the dryer to vibrate.
Review the"Exhausting'section
on page 13 before installing the exhaust system.
Install the ductwork from your dryer to the exhaust hood.The crimped
end of the duct sections must point
away from your dryer.
DQ NOT use sheet metal screws when assembling
the ducting.Thesejoints
should be taped.
Never use plastic flexible exhaust material.
Tip for tight installations: install a section of the exhaust system onto your dryer before putting it in place.
Use duct tape to secure this section to your dryer, but do not cover the ventilation
slots at the back of
the unit in dryer cabinet.
Review the"Electrical
requirements"
section on page 16.
BEFOREOPERATING OR TESTING, follow the grounding
instructions
in the"Grounding"section
on page 9.
_IL
WARNING-
U.S. MODELS
RISK OF ELECTRIC SHOCK - All U.S.models are produced for a S-WIRE SYSTEM CONNECTION.
The dryer frame is grounded
to the neutral conductor
at the terminal block.
A 4-WIRE SYSTEM CONNECTION
is required for new or remodeled
construction,
mobile homes, or if
local codes do not permit grounding
through
the neutral conductor, if the 4-wire system is used, the
dryer frame cannot be grounded
to the neutral conductor
at the terminal
block.
Refer to the following
instructions
lot"Electrical
connections"
on page 16.
Remove the terminal block cover plate.
Insert the power cord with a Ublisted strain relief through the hole provided in the cabinet near the terminal
block.
A strain
must
relief
be used.
Do not loosen the nuts already installed on the terminal
block. Be sure they are tight.
Use a 3/8 in. (1 cm) deep well socket.