INSTRUCTION MANUEL. PROMAX-8+
APPENDIX E.- CARRIER / NOISE RATIO MEASUREMENT (C/N)
Example
Suppose that the video carrier level for an analogue channel, is of 20 dBmV,
from the diagram we can deduce that the measurement range is of 48 dB.
Thus, if when we carry out the measurement the C/N ratio is 54 dB the display
will show C/N > 48 dB.
On the other hand, if C/N=42 dB we will see on the display C/N = 42 dB.
May 2001
Figure 44.- C/N ratio measuring range.
Page 45