Celsius/Fahrenheit Toggle Button:
or Fahrenheit. The system's default is Celsius.
Ozonator Button:
activated. For bathers' safety concern, the ozonator cannot be operated at the same time
when the Bubbling function is on. The Ozonator will be off automatically after opearting for 2
hours. Ozone output is 30-50mg/Hr.
NOTE: Please do not soak in the spa when the Ozone is on. The Ozonator will not work
when the spa has no water or when the Bubble Button is on.
IMPORTANT:The following conditions will lead to slow water heating
● The ambient temperature is lower than 10°C(50°F)
● Outdoor wind speed is above 3.5-5.4m/s(8-12mph)
● The air bubble function is activated when heater is on
● The spa is not properly covered with the spa cover when heater is on
ERROR CODE CHART
LCD READING
Water temperature is lower than zero
degree or exceed 55°C(131°F)
E0
Temperature sensor failure
Water pressure switch failure
Filter failure
E1
Water level is not at minimum water line
Detecting function failure
E2
No water in the spa tub
E3
System failure
Heating failure
E4
Activate the Ozone. The Ozone icon shows when the Ozone function is
CAUSE
17
The temperature can be displayed in either Celsius
SOLUTION
Change the water or contact the MSpa
Service Center.
Contact the MSpa Service Center.
Add more water to the minimum line.
Contact the MSpa Service Center.
Add more water to the minimum line.
System self-checking
Step 1: Fill water to the water line, and make
sure that there is no bather or
object in the spa tub.
Step 2: Connect the power supply, press
RESET button on the PRCD.
Step 3: If E3 shows, contact the MSpa
Service Center. If E3 is flashing,
press ON/OFF, C/F,TEMP + buttons
once insequence, enter to the
self-checking system. If no error
code shows, failure is not detected.
It is OK to use the spa. If error code
shows after self-checking, contact
the MSpa Service Center.
Contact the MSpa Service Center.