Air Conditioner DC Duct Type
Check the leakage
Check all the joints with the leak detector or soap
water.
Insulation
Be sure to with insulating materials cover all the
exposed parts of the flare pipe joints and
refrigerant pipe on the liquid-side and the gas-
side. Ensure that there is no gap between them.
Incomplete insulation may cause water
condensation.

10. CONNECT THE DRAIN PIPE

1. Install indoor unit drain pipe
The outlet has PTI screw bread, Please use
sealing materials and pipe sheath (fitting) when
connecting PVC pipes.
CAUTION
The drain pipe of indoor unit must be heat
insulated, or it will condense dew, as well as the
connections of the indoor unit.
Hard PVC binder must be used for pipe
connection, and make sure there is no leakage.
With the connection part to the indoor unit,
please be noted not to impose pressure on the
side of indoor unit pipes.
When the declivity of the drain pipe downwards
is over 1/100, there should not be any win ding.
The total length of the drain pipe when pulled out
traversely shall not exceed 20m, when the pipe is
over long, a prop stand must be installed to
prevent winding.
Refer to the figures on the right for the
installation of the pipes.
2. Drainage test
Check whether the drainpipe is unhindered
New built house should have this test done before
paving the ceiling.

11. WIRING

Attaching wiring
1. The air conditioner should use separate power
supply with rated voltage
2. The external power supply to the air conditioner
should have ground wiring, which is linked to the
ground wiring of the indoor and outdoor unit.
3. The wiring work should be done by qualified
persons according to circuit drawing.
4. Aleakage protector should be installed
according to the National Standard concerning
electrical appliance.
5. Be sure to locate the power wiring and the
signal wring well to avoid cross-disturbance and
their contact with connecting pipe or stop value
body.
6. The wiring attached to this air conditioner is
10m long. Be sure to prolong it with wiring of the
same type and proper length if necessary.
Generally, do not twist two wiring together unless
the joint is soldered well and covered with
insulator tape.
7. Do not turn on the power until you have checked
carefully after wiring.