17. MALFUNCTION CODE
OF OUTDOOR UNIT
Display
Malfunction or Protection
E0
EEPROM malfunction
E2
Communication malfunction between
indoor/outdoor units
E3
Communication malfunction between
DSP/outdoor units
E4
T4 temperature sensor
malfunction
E5
Compressor Voltage protection
P0
Compressor Top Temperature
Protection
P1
High Pressure Protection
P2
Low Pressure Protection
P3
Compressor current protection
P4
Compressor discharge temperature
protection
P5
Protección de alta temperatura
P6
Module protection
CAUTION
Please cut off the power supply when appearing
the above malfunction, check the voltage provided
is out of range, check if the installation of air-
conditioner is correct, then electrify again after 3
minutes power off. If the problemis still existent,
please contact the local service station or the
equipment provider.