Thank you for buying this Briteq
product. To take full advantage of all possibilities and for your own safety, please read
these operating instructions very carefully before you start using this unit.
FEATURES
This product meets the requirements of the current European and national guidelines. Conformity has been established
and the relevant statements and documents have been deposited by the manufacturer.
 This device has been designed to produce decorative effect lighting and is used in light show systems.
 Multifunctional light projector
 Produces the same light output as a 1000 W PARprojector. Thanks to the special HPL 575-X lamp, this projector only
consumes 575 Watt
 4 lenses (very narrow, narrow, medium flood, wide flood) are included
 Available in black or silver
 Optional: barndoors

BEFORE USE

 Before you start using this unit, please check if there's no transportation damage. Should there be any, do not use the
device and consult your dealer first.
 Important: This device left our factory in perfect condition and well packaged. It is absolutely necessary for the user to
strictly follow the safety instructions and warnings in this user manual. Any damage caused by mishandling is not
subject to warranty. The dealer will not accept responsibility for any resulting defects or problems caused by
disregarding this user manual.
 Keep this booklet in a safe place for future consultation. If you sell the fixture, be sure to add this user manual.
Check the contents:
Check that the carton contains the following items:
 Operating instructions
 Multipar (Silver/Black)
 Colour frame
 4 lenses (very narrow, narrow, medium flood, wide flood) are included

SAFETY INSTRUCTIONS:

CAUTION: To reduce the risk of electric shock, do not remove the top cover. No user-
CAUTION
serviceable parts inside. Refer servicing to qualified service personnel only.
The lightning flash with arrowhead symbol within the equilateral triangle is intended to alert the use or the
presence of un-insulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude
to constitute a risk of electric shock.
The exclamation point within the equilateral triangle is intended to alert the user to the presence of important
operation and maintenance (servicing) instructions in the literature accompanying this appliance.
This symbol means: indoor use only.
This symbol means: Read instructions.
This symbol determines: the minimum distance from lighted objects. The minimum distance between light-
output and the illuminated surface must be more than 2 meters.
 To protect the environment, please try to recycle the packing material as much as possible.
 A new light effect sometimes causes some unwanted smoke and/or smell. This is normal and disappears after some
minutes.
 To prevent fire or shock hazard, do not expose this appliance to rain or moisture.
 To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when bringing it
into a warm room after transport. Condense sometimes prevents the unit from working at full performance or may even
cause damages.
 This unit is for indoor use only.
 Don't place metal objects or spill liquid inside the unit. Electric shock or malfunction may result. If a foreign object
enters the unit, immediately disconnect the mains power.
BRITEQ
®
OPERATION MANUAL
1/35
MULTIPAR
ENGLISH
 Locate the fixture in a well ventilated spot, away from any flammable materials and/or liquids. The fixture must be fixed
at least 50cm from surrounding walls.
 Don't cover any ventilation openings as this may result in overheating.
 Prevent use in dusty environments and clean the unit regularly.
 Keep the unit away from children.
 Inexperienced persons should not operate this device.
 Maximum save ambient temperature is 40°C. Don't use this unit at higher ambient temperatures.
 The units' surface temperature may reach up to 85°C. Don't touch the housing with bare hands during its operation.
 Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging and servicing.
 Allow the device about 10 minutes to cool down before replacing the bulb or start servicing.
 Always unplug the unit when it is not used for a longer time or before replacing the bulb or start servicing.
 The electrical installation should be carried out by qualified personal only, according to the regulations for electrical
and mechanical safety in your country.
 Check that the available voltage is not higher than the one stated on the rear panel of the unit.
 The power cord should always be in perfect condition. Switch the unit immediately off when the power cord is
squashed or damaged. It must be replaced by the manufacturer, its service agent or similarly qualified persons in order
to avoid a hazard.
 Never let the power-cord come into contact with other cables!
 This fixture must be earthed to in order comply with safety regulations.
 Always use an appropriate and certified safety cable when installing the unit.
 In order to prevent electric shock, do not open the cover. Apart from the lamp there are no user serviceable parts
inside.
 Never repair a fuse or bypass the fuse holder. Always replace a damaged fuse with a fuse of the same type and
electricalspecifications!
 In the event of serious operating problems, stop using the fixture and contact your dealer immediately.
 The housing and the lenses must be replaced if they are visibly damaged.
 Please use the original packing when the device is to be transported.
 Due to safety reasons it is prohibited to make unauthorized modifications to the unit.
Important: Never look directly into the light source! Don't use the effect in the presence of persons suffering from
epilepsy.
INSTALLING THE POWER PLUG
When you instal the power plug (at least 2.5A type), you have to connect the wires according to the following color
codes:
Green and yellow
=
Blue
=
Brown
=
Important remark: this projector must be earthed

LAMP (RE)PLACEMENT

This projector can only be used with a special HPL 575-X lamp. In case of
replacement of the lamp or maintenance, do not open the fixture within 10
minutes until the unit cools down after switching off. Always unplug the unit
before servicing! Always use the same type of spare parts (bulbs, etc.) When
replacing parts, please only genuine spare parts.
 Switch off the unit and unplug the mains cable.
 Wait for about 10 minutes until the unit has been cooled down.
 Use a screwdriver to unscrew the screw that closes the lamp compartment on the back of the
projector (A on the picture below).
 Tear the lamp socket gently out of the lamp compartment. (See D on the picture below)
 Unplug the old lamp. Hold the lamp socket while unplugging the lamp
 Hold the lamp socket while pressing the new lamp gently in the socket.
Attention! Check the label on the backside of the device or see the technical specifications in this
manual to know which lamp should be used. Never install lamps with a higher wattage! Lamps with
higher wattage generate temperatures the device was not designed for. If the device uses a lamp
transformer, it will burn due to current overload.
 Don't touch the bulb with bare hands! This drastically shortens the lifespan of the lamp. If you
touched the lamp, clean it with a cloth and a little denatured alcohol. Wipe the lamp off before
installing.
BRITEQ
®
OPERATION MANUAL
Earth connection
Neutral
Live