INSTALLATION
INSTALLATION
Risk of damage through overturning.
The water heater has a high centre of gravity and a
low overturning moment. Protect the water heater
against overturning.
Only position the water heater on a level substrate.
To protect the water heater against damage, it should be
transported vertically inside its packaging. Where space is
restricted, you can also tilt (max. 45°) the water heater briefly
to move it.
11.4 Storage
Where it is necessary to store the water heater prior to installation
for a longer period, observe the following:
- If possible, store the water heater in a dry and dust-free
ambience.
- Prevent the water heater from coming into contact with
aggressive materials.
- Prevent the water heater from being exposed to shocks or
vibrations.
- In case of prolonged storage, check the condition of the
water heater and its packaging regularly.
11.5 Positioning the water heater
» Position the water heater with its wooden pallet at the final
installation location in a 10' x 10' x 8' area.
Install the water heater so that there is an adequate clearance
adjacent to the air grilles (see the following diagrams).
11.5.1 Installation conditions
It is important for water heater performance and to avoid damage
to adjacent surfaces that adequate clearance remains available
on the air flow intake (min. 2') and air flow exhaust sides (min
6') of the unit.
It is important for water heater maintenance that adequate space
remains available above the water heater.
16
| ACCELERA® 300 HEAT PUMP WATER HEATER
15 ¾˝ (0.4 m)
Air flow
intake
2´ (0.6 m)
Acceptable positioning, vent parallel side wall:
2´ (0.6 m)
Air flow
intake
Acceptable positioning, vent towards room center:
2´ (0.6 m)
Air flow
intake
2´ (0.6 m)
» Level the water heater horizontally by adjusting the feet.
11.6 Unpacking the water heater
Ensure that the casing material in the lower section
will not be damaged.
Advice - The longer you keep the packaging foil
wrapped around the water heater, the longer it will
be protected against damage.
Air flow
exhaust
6´ (1.8 m)
Minimum room
volume: 800 ft
2
(10´ x 10´ x 8´)
8˝ (0.2 m)
6´ (1.8 m)
Air flow
exhaust
Air flow
exhaust