11.i Location
Choose a position to mount the pump that is dry and away from standing water and is free
from obstacles.
Mount in a position with the shortest pipe run lengths possible.
11.ii Mounting Instructions
Gulper® IC can be mounted on a horizontal or vertical surface.
When mounted vertically ensure that the pump head is lower
most (Fig 3).
NOTE -It is recommended that the outlet is mounted above the water
line and anti-syphon loops are fitted where applicable (see typical
installation Figs 1 - 2).
When mounting, position the pump on surface and work-out the best angles for the hose (to
prevent kinking) and mark the 3 hole positions using the pump feet.
NOTE: The pump head may be rotated to suit the hose connections. Loosen the screw, adjust and
reposition the head to the required position (Fig 4) and tighten the screw
Drill pilot holes of 3.2mm (1/8").
NOTE: Do not drill through hull, ensure that pump is mounted to additional board or bulkhead.
Use the three No.8 self tappers and washers (included) to secure the pump.
Use 19mm (3/4") or 25mm (1") smooth bore reinforced hose to connect to the pump with
hose
clips.
NOTE: Barbed connections mean there is no need to cut inlets or outlets to size.
NOTE: Ensure tight connections, but do not over-tighten clamp rings/ screws/hose clips
Fig 4 - Gulper® IC Installation
Screw p clamp to bulkhead ensuring it is located approx. 100 mm (4") from rear housing (Fig
5).
NOTE: In order to securely fasten the unit, ensure that the P clamp mounting surface is at least
19mm (3/4") minimum thickness.
11.iii Electrical Wiring
For installation with Whale® IC accessories use pre-wired Deutsch® connectors attached
For installation to non-whale systems - use spade connector adaptor AK2081- available
separately
If you are not familiar with applicable electrical standards, ensure that the unit is installed by
a qualified electrician/ technician.
WARNING: Fire hazard. Wiring must comply with applicable electrical standards and include a
properly sized fuse or circuit breaker. Improper wiring can cause a fire resulting in injury or death.
NOTE: Switch off the power prior to making connections. Suggested wiring information is given as a
guide only. For full information, refer to the USCG, ABYC and ISO regulations for marine
applications and wiring gauges, connectors and fuse protection.