Use
4.4

Menu inputs

The following settings and information is available in the device
software:
Zero point adjustment
Unit of measurement
Measuring time (setting the timer)
Auto switch-off (switch-off times for battery and power
supply unit operation)
Contrast/Brightness
Date (setting and display format)
Time (setting and display format)
Language
Display mode (pressure and flow display in long or short
form)
Device information (part number, serial number, next
calibration date)
Software version
4.5

Before first use (optional)

4.5.1

Perform the basic settings in the device software

1. Switch on the test device: Hold the
2 seconds.
2. Push the
button.
M
3. Set the language, time and date as well as the display
mode. Confirm the selected setting with the
4. Exit the menu: Select the "Back to measurement" entry and
push the
button.
OK
4.5.2
Install the test software on the PC and create the
data
The use of the test software requires proficiency in MS
Windows.
The PC on which the test software is to be installed must meet
the following minimum requirements:
Processor: 1.6 GHz or higher
RAM: 2 GB or higher
Free disk space: >500 MB
Operating system: Windows 7 or Windows 8
1 free USB port
The monitor resolution should be set to 1024 x 768.
NOTICE
i
i
For installation, the user must have administrator
rights for the PC.
1. Download the "Dräger Protector Software" test software
from the Dräger website (www.draeger.com/software) and
unzip, if required.
2. Run the "Protector.exe" file.
3. Follow the setup program instructions.
The required components of the program are installed in
the selected folder and an entry is created in the start
menu.
4. Observe the information displayed during installation.
12
5. Restart the PC and log in.
i
i
6. Import the desired device data with the test settings. The
7. Create other users as well as respirator products,
i
i
4.6
button down for
OK
!
button.
OK
4.6.1
1. Connect the test device to the power supply, if applicable.
2. Switch the test device on:
4.6.2
1. Access the test software.
2. If the login screen appears, enter the user name and
i
i
NOTICE
The following user names are available on delivery of
the test software:
User name "Chief" with password "Createdata"
User name "admin" with password "admin"
following records are available:
for the EU database in the EU folder:
-
mask_EU.zip (device data for full face masks)
-
BG4_EU.zip
(device
breathing apparatus)
customers and locations in the test software, if required,
and review the settings in the "Extras" menu.
NOTICE
Additional information can be found in the "Help" menu
in the test software.

Before every use

CAUTION
The connection for the equipment to be tested must be
open (the system is depressurised) when starting the
test device so that the pressure sensors can adjust to
the current ambient pressure. Otherwise, no tests can
be conducted. In this case, an error message is
displayed.
Prepare test device
hold the
button down for 2 seconds.
OK
The sensor offset adjustment takes place automatically
after the device is switched on.
Start the test software on the PC (optional)
password (password see chapter 4.5.2 on page 12).
NOTICE
The display function of the display is switched off
during operation with the PC and the current
communication is displayed by the message "PC-
MODE".