TO REPLACE POWER CORD ONLY
1.
Remove capacitor housing as described above.
Disconnect cord leads from motor and remove ground
screw.
2.
Unscrew cord bushing and remove from housing. Fig. 14
3.
Replace with new fitting and cord, be sure "O" ring seal
is in place. Fig. 14
4.
Replace ground screw and re-connect motor wires.
Wiring diagram is given in these instructions.
5.
Replace capacitor housing and refill motor with Myers
submersible oil. See Fig. 13 for oil level. One inch from
top of casting.
COMPLETELY DISMANTLE PUMP TO
REPLACE MOTOR STATOR AND SEAL
1.
Pour oil from motor and remove capacitor housing as
described above.
2.
Remove bolts from motor housing only. Do not remove
bolts that hold motor plate to volute case. Fig. 15
3.
Lift off motor housing, pry between ears to loosen.
Fig. 16
4.
Remove case holding bolts and lift out rotating unit. Pry
between ears to loosen. Fig. 17
5.
Hold rotor and unscrew impeller locking nut. Turn
counter-clockwise as thread is right hand. Fig. 18.
6.
Unscrew impeller, turn counter-clockwise to loosen.
Fig. 19
7.
Pry off seal with screwdrivers. It is not important if seal is
damaged, as it must be replaced. Replace both parts of
seal, never one or the other. Fig. 20.