Hood Exhaust; Outside Top Exhaust - GE JVM1950 Instrucciones De Instalación

Ocultar thumbs Ver también para JVM1950:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
Instructions
HOOD EXHAUST
NOTE:Read these next two pages only if you plan to vent your exhaust to the outside.
If you plan to redrculate the air back into the room, proceed to page 6.
OUTSIDE TOP EXHAUST
(EXAMPLE ONLY)
The following chart describes an example of one possible
ductwork installation.
DUCT PIECES
D
Roof Cap
12 Ft. Straight Duct
(6" Round)
Rectangular-to-Round
Transition Adaptor*
EQUIVALENT
NUMBER
EQUIVALENT
LENGTH
x
USED
=
LENGTH
24 Ft.
x
(!)
12 Ft.
x
(!)
5 Ft.
x
(!)
Equivalent lengths of duct pieces are based on actual tests and
reflect requirements for good venting performance with any vent hood.
Total Length
24 Ft.
12 Ft.
5 Ft.
41 Ft.
*IMPORTANT: If a rectangular-to-round
transition adaptor is used, the bottom corners of the damper will
have to be cut to fit, using the tin snips, in order to allow free movement of the damper.
OUTSIDE
BACK EXHAUST
(EXAMPLE ONLY)
The following chart describes an example of one possible
ductwork installation.
[
DUCT PIECES
Wall Cap
3 Ft. Straight Duct
3¼" x !0" Rectangular)
90 ° Elbow
EQUIVALENT
NUMBER
EQUIVALENT
LENGTH*
x
USED
=
LENGTH
40 Ft.
x
(!)
3 Ft.
x
(!)
!0 Ft.
x
(2)
Equivalent lengths of duct pieces are based on actual tests and
reflect requirements for good venting performance with any vent hood.
Total Length
40 Ft.
3 Ft.
20 Ft.
=
63 Ft.
NOTE: For back exhaust, care should be taken to align exhaust with space between studs, or wall should be prepared
at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
4