• TEMPERATURE VALUES.
Used to set all the temperature values utilized for manual, anti-
freeze, automatic (temperature levels T1, T2, T3) and temperature
differential operation .
- Manual.
Press key P until the required mode is displayed (temperature
blinking); using key "" "" set the required temperature,
then press the OK key to confirm and pass on to setting
antifreeze .
- Antifreeze.
Using key "" "" (TEMP lit up steady and temperature value
blinking), set the antifreeze value (from 4 to 15 °C), then press
the OK key to confirm and pass on to setting temperature
level T1 .
- Level T1.
Using key "" "" (TEMP and T1 lit up steady and tempe-
rature value blinking), set the required value for level T1, then
press the OK key to confirm and pass on to setting tempera-
ture level T2 .
32 - ENGLISH
- Level T2.
Using key "" "" (TEMP and T2 lit up steady and tempe-
rature value blinking), set the required value for level T2, then
press the OK key to confirm and pass on to setting tempera-
ture level T3 .
- Level T3.
Using key "" "" (TEMP and T3 lit up steady and tem-
perature value blinking), set the required value for level T3,
then press the OK key to confirm and pass on to setting the
temperature differential .
- Temperature differential.
Using key "" "" (TEMP and dIFF lit up steady and value
blinking), set the required value for the temperature differential
(from 0 .1 to 1 °C), then press the OK key to confirm and exit
the menu .