Tests And Approvals; Residual Risk - Alto SQ 691-9M/B1 Instrucciones De Manejo

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 118
of the cleaner from the
tank. For the subse-
quent removal of the
deflector and the filter
element, place the top
part of the cleaner top
down on a suitable sup-
port (Fig. 9).
Remove the five screws
(Fig. 9/2).
Remove the deflector
(Fig. 9/1) on the top
part and put it aside.
Remove
the
locking washer (Fig.
10/1) with the supplied
Allen key.
Place the filter protec-
tive bag completely
over the filter element
(Fig. 10/2) and pull off
the filter element.
After the removal: Seal
the filter protective bag
with a knot.
Install a new filter ele-
ment, put the filter
locking washer in place
and install and tighten
the filter clamping nut.
Dispose of the removed
filter element in ac-
cordance with the ap-
plicable national regu-
lations.
NOTE!
14
Maintenance services other
than those described above
may only be carried out by
authorised personnel.

TESTS AND APPROVALS

The SQ 691-9M/B1 cleaner
is tested in accordance with
the valid DIN EN 60335-1
test procedures and spe-
cifications.
The vacuum cleaner also
conforms to the require-
ments of EU standard EN
filter
60335-2-69, dust class M.
It is therefore suitable for
vacuuming dusts with
maximum workplace con-
centration values >0.1 mg/
m³ and wood dusts.
The cleaner and its ac-
cessories conform to the
dust explosion protection
for industrial vacuum
cleaners, type 1 (ignition
source free type).
They therefore can be
used for collecting dusts
of dust explosion classes
St 1, St 2 and St 3 in zone
11 for heavy duty in
commercial applications.
The cleaner was found to
be suitable for the collec-
tion of propellant charge
powder residues (max. 10
% uncombusted powder)
by the German Technical
Safety Association (TÜV).
When doing tests and/or
repairs, the safety rules
(VBG 4) and also of DIN
VDE 0701 Parts 1 and 3
must be observed and
applied strictly.
The electrical safety in-
spections according to DIN
VDE 0702 are required at
regular intervals and also
after repairs and after
modifications to the clea-
ner.
A dust safety inspection
must be performed at
least annually by the
manufacturer or by an
instructed person, eg for
damage to the filter, for
leaks and for proper op-
eration of the controls.

RESIDUAL RISK!

The functional check of the
safety features of the vac-
uum SQ 691-9M/B1 must
be carried out before each
start-up - in this way it is
ensured that no explosion
hazard can occur during
operation.
At the end of the vacuum
cleaner's service life, detach
the power cable and dis-
card the cleaner in ac-
cordance with applicable
regulations.

Publicidad

Tabla de contenido
loading