TROUBLESHOOTING
The purpose of the following information
is to identify and correct possible faults
and malfunctions that may occur when
using the machine.
Some failures may be resolved by the us-
Problem
The robot is very
noisy
The robot stopped
with the led (E)
(green) on and the
led (H) (yellow)
E
F
flashing.
C
D
B M
G H
The robot stopped
A
with the led (F)
(red) flashing and
the led (H) (yellow)
on.
L
FAILURES, CAUSES AND SOLUTIONS
Causes
Damaged cutting blade
The perimeter wire is not
correctly connected (bro-
ken wire, lack of electric
connection, etc.).
Excessive ground slope.
Perimeter cable incor-
rectly placed.
Perimeter wire marking
inside areas (beds, bush-
es, etc.) placed clockwise.
Overheated power supply
unit
The wheel drive is not
correct
er; others require precise technical skills
or special abilities and must be exclusive-
ly resolved by qualified personnel with
certified experience, achieved in the spe-
cific intervention field.
Solutions
Replace the blade with a new
one.
Check that the power supply
works and that the connec-
tion of the power supply-trans-
mitter unit is correct.
Mark the area with excessive
gradient.
Check that the wire is in-
stalled properly (too deep,
close to metal objects, dis-
tance between the wire that
marks two elements less
than 70 cm, etc.).
Relocate the perimeter wire
correctly (anticlockwise direc-
tion).
Adopt suitable solutions to re-
duce the temperature of the
power supply unit (air or
change the installation area,
etc.).
Check and, if necessary, ad-
just the chain tensioning.
- 37 -