Connection Plugs; Powerdial; Powerbar; Economy Switch - Generac iQ2000 Manual Del Propietário

Ocultar thumbs Ver también para iQ2000:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Connection Plugs

120 VAC, Duplex Receptacle
The 120 Volt outlet is overload protected by
the inverter module electronic control. See
Figure
2-4. Each receptacle will power 120
Volt AC, single phase, 60 Hz electrical loads
requiring up to 1600 watts (1.6 kW).
NOTE: Limit length of extension cords to fif-
teen feet, or less, to prevent voltage drop and
overheating of wires.
Figure 2-4. 120 VAC, Duplex Receptacle

PowerDial

The PowerDial controls the ON/OFF func-
tions, choke and fuel valve operation. See
ure
2-5.
• The START position (1) is used to start the
engine. In this position, the fuel is on and
the choke is fully on (closed).
• The RUN position (2) for normal operation
and to gradually reduce the use of the
choke.
• The STOP position (3) stops the engine
and shuts off fuel flow.
2
1
Figure 2-5. PowerDial (example)

PowerBar

The PowerBar indicates the amount of power
being used from the generator. Each section
is approximately 20%.
6

Economy Switch

The economy switch has 3 modes of opera-
tion:
• Economy: The quietest mode and best
when running appliances or equipment that
are resistive loads (non-motor starting),
(example: TV, video game, fan, light, radio).
• Standard: Best when running a both induc-
tive (motor-starting loads) and resistive
(non-motor starting loads), especially when
these loads are turning on and off (exam-
ple: RV, air conditioner).
• Turbo: Best when running inductive loads
(appliances or equipment with motor-start-
ing) that are continually running (examples:
drill, blender, saw, hairdryer).

Generator Status Lights

See
Figure
• Over Temperature LED (red): Illuminates
when unit temperatures exceed normal
operating conditions (1). The ready LED
will turn off and the inverter will cut power to
the outlets. Check for airflow obstructions
000424
at front and rear panels. The engine will
remain running to cool the unit with the over
temperature LED illuminated. Once the unit
has reached normal operating tempera-
tures, the over temperature LED will turn
off. The reset button must then be pressed
Fig-
for 1 second and released to clear the fault
and restore output power.
• Low Oil Level LED (orange): Illuminates
when oil level is below safe operating level.
Engine shuts down (2).
• Ready LED (green): Indicates output from
generator (3) (unless there is a low oil or
overload condition).
• Overload LED (red): Indicates system
overload (4). During motor starting it is nor-
mal for the overload LED to illuminate for a
few seconds. If LED stays illuminated and
the ready LED turns off, the engine will con-
tinue to run without output power. Remove
all applied loads and determine if attached
devices
power. Review for any faulty or shorted
3
connections. Press and hold the reset but-
ton for 1 second and release. The red over-
load LED should turnoff. Loads can be re-
applied once the green ready LED illumi-
nates. If the red LED returns, contact an
IASD.
000663

Run Time Display

See
Figure
play (7) shows the total engine hours of the
unit, then transitions to show the Run Time
Remaining.
2-6.
exceed
recommended
2-6. At startup the Run Time Dis-
Owner's Manual for Portable Generator
output

Publicidad

Tabla de contenido
loading

Tabla de contenido