2.3.5. General parameters
Access to parameter menu
Access to the parameter value
Change value: Decrease
Confirm value
It is possible to modify the general operation parameters at any moment such
as charging configuration, temperatures units...
During any operation mode, access the general configuration menu as stated in
the general configuration section (Section 2.3) and press
the text "PArA." is displayed to access the general parameters menu.
UP01 will be displayed.
Use
and
to move on through the different parameters.
Use
to access the parameter you want to modify. Change the value using
the navigation keys
and
It is possible to save the changes and exit at any moment by pressing
Ecombi Plus general parameters that can be modified by the user are.
- UP01: Initial % of storage charge.
- UP02: Starting time of reduced (off-peak) rate electric period.
- UP03: Ending time of reduced rate electric period.
- UP04: Starting time of the second reduced rate electric period. (if not
available set up 00:00).
- UP05: Ending time of the second reduced rate electric period. (if not
available set up 00:00).
- UP06: Charging days during the week.
- UP07: Temperature ambient sensor correction (values from -5ºC to
5ºC).
- UP08: Maximum working period of the balancing heating element in on
peak electric period. Set up this value to "0" to cancel the balancing
heating element operation in on peak electric periods. With balancing
heating operation cancelled, the charge correction will not operate and
the same charging level will be applied every day. (Default 5 hours)
- UP09: Excess of temperature protection during the charge, Degrees
higher than the comfort set point temperature (Programme Mode) or
the set point temperature (Basic Mode) when the charge is interrupted.
(Values 1,2,3,4 & 5).
- UP10: Degrees Celsius or Fahrenheit. (Values: ºC – F).
- UP11: Open Window Detection Activation. (On/Off).
- UP12: Adaptive Start Control Activation (On/Off).
- UP13: Kind of temperature control. Recommended & default PID.
- UP14: Weekend Balancing Element restriction. The maximum working
hours for the balancing element set in UP08 can be disabled for
weekends by setting Off this parameter. (By default: On)
i
ECOMBI PLUS does not change automatically from summer time to winter
time or vice versa when not connected to the internet. Depending on the tariff it may
be necessary to change the clock settings to fit these two timings
27
. Confirm the new value with
button when
.
.