3.- REMOTE OPERATION USING THE WIFI G-CONTROL HUB
It is possible to control the full operation of the unit remotely with the Elnur Wifi Control app or the app-web. The unit must be
connected to a Wifi G-Control Hub connected to the internet to use this feature.
3.1 To associate the unit to the G-Control Hub, the discovery mode of the hub must be activated. Press the associate button at
the back of the Gateway for 3 seconds. An orange flashing light every second indicates association mode.
3.2 With the hub in association mode, press
You can control and adjust the programming and temperatures on the Ecombi Plus via the Elnur Wifi Control app.
3.3 To disassociate the unit, a reset of the unit must be realized. See "Default settings and unit reset". When the storage
heater is reset, it will remove the programming and revert back to the default settings and also disassociate from the RF
network and G-Control Hub.
4.- TROUBLESHOOTING
ECOMBI PLUS does not heat.
ECOMBI PLUS does not reach
set up temperature
"Err" Message in display
Keyboard does not respond
ECOMBI PLUS does not
communicate with the G
Control Hub.
on the storage heater for 3 seconds until the Link symbol
Please check it is connected and switched on.
Make sure the device is not covered or the lower air inlets are not obstructed. The LR safety limit
may be activated; in this case it is necessary to reset it manually. Please contact technician.
Make sure that adequate temperature is selected.
Make sure the storage heater is sized correctly for heat loss.
Please contact technician.
If the symbol
is displayed, the keyboard is locked. Hold "+" and "-" buttons simultaneously for 3
seconds to unlock the keyboard. (See Keyboard Lock Section).
Check the unit is associated, the symbol
For distances greater than 30 metros and 2-3 walls, associate first the closest units. Each unit can
work as signal extender.
If
symbol is flashing, check the G Control Hub connexion to the network, and if any other
device in the RF Net that could be working as signal extender has been removed.
must be shown on the display LCD.
31
is shown.