FAULT
The band rotation motor does not
work.
Machine does not work.
Motor stopped with pilot light "Hl2"
lit.
PROBABLE CAUSE
"SA1" two speed switch
Main motor over-load relay
"SB1" emergency switch
"SB2" start push button
Fuses "FU"
"SQ1" automatic shut-off limit switch
"SQ2" blade cover limit swich
"SQ3" blade broke limit switch
Speed switch "SA1" in position "0"
Emergency button "SB1" on
"SB3" trigger switch
Main motor
"SB3" trigger switch
Main motor
REMEDY
It must be exactly turned towards Rabbit or
Turtle sign.
Push down FR1 red button. After a motor
cooling time of 5 minutes, if there is no current
continuity on these two wires
must be replaced
R e s e t e m e r g e n c y s w i t c h ( s e e o p e r a t i o n
procedure).
Check the functioning and /or possible damage.
If so, replace it.
Check electrical efficiently
fuse
Refer to the operation procedure and adjust the
switch if machine doesn t shut off after the
material completely cuts. Replace
damaged
Check closing of the fly wheel cover. Check the
efficiency of the device
replace it if damaged.
Check the efficiency of the device
if damaged.
It must be exactly turned to the Rabbit or Turtle
sign.
Reset the emergency switch by following the
steps of operation procedure. Check electrical
efficiency, if not, replace it.
Check the efficiency of the device
Check current continuity on the two wires in the
prone
if not
replace the motor
Check the efficiency of the device
it damaged.
Check that it is burnt and that it turns freely
Replace it if it damaged
the motor
If not
replace the
it
if
it
replace it
replace it
replace it if