Connecting The Electrical Power To The Generator - Dometic TEC 60 Instrucciones De Montaje

Ocultar thumbs Ver también para TEC 60:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57
TEC60, TEC60LPG
10
Connecting the electrical power to the
generator
D
DANGER! Danger of electrocution
Make sure there is no voltage at electrically operated components
before carrying out work on them!
I
NOTE
Observe the applicable guidelines in the country of the consumer.
10.1
Important notes on the electrical connection
• Only a qualified electrician should connect the generator to the electrical power.
• Check that the voltage specification on the type plate is the same as that of the
power supply.
• Do not lay the 230 Vw mains cable and the 12/24 Vg cable together in the
same cable duct.
• Do not lay cables which are loose or bent next to electrically conductive material
(metal).
• Connect the generator to a power circuit which can supply the necessary current
(see chapter "Technical data" on page 27).
• Select the cross-section of the cable as follows:
– 230 V: 6 mm²
– Battery connection (length < 6 m): 16 mm²
– Battery connection (length > 6 m): 25 mm²
• Install a manual main switch which can disconnect all the consumers from the
generator with the exception of the battery.