disables the Starting Torque function, while if Soft Start is disabled then
Starting Torque is automatically enabled.
3. SAFE 1 also in opening:
The control unit allows the operation of input DS1 to be modified. If you want
SAFE 1 to operate also during opening (momentary stopping of the gate, as
soon as it is freed the control unit resumes the opening movement), proceed
as follows: ensure you have enabled Extended Menu 2 and then press the
SEL key to select blinking LED L3 and press the SET key: LED L3 becomes
steady on and programming will be completed.
Repeat the procedure if you wish to restore the initial configuration.
4. HOLD-TO-RUN:
The control unit provides the opportunity to set the "Hold-to-run" function.
If you wish to enable this function, proceed as follows: ensure you have
enabled Extended Menu 2 and then use the SELECT key to select blinking
LED L4 and press the SET key; at the same time LED L4 becomes steady
on and the operation will be completed.
With this function enabled using either the remotes or the Pushbuttons to
operate the gate, the following operation will be obtained: the command must
be kept maintained constantly to move the gate. When the command is
released, movement will stop immediately. Repeat the procedure if you wish
to restore the previous configuration.
5. FOLLOW ME
The control unit allows the "Follow me" function to be configured;
programmable only if a Pause Time has already been set, this function
reduces the Pause Time to 5 seconds after freeing the SAFE1 photocell,
meaning the gate re-closes 5 seconds after transit of the user. To activate
this function proceed as follows: ensure you have enabled Extended Menu 2
and then press the SELECT key to select blinking LED L5 and then press the
SET key: LED L5 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
6. FLASHING LIGHT OPERATION:
The control unit is factory set with Flashing Light during Pause Time disabled.
If you wish to enable this function, proceed as follows: make sure you have
enabled Extended Menu 2, press the SELECT key to select blinking LED L6
and then press the SET key: LED L6 becomes steady on and programming
will be completed. Repeat the procedure if you wish to restore the previous
configuration.
7. ALWAYS CLOSE FUNCTION:
The control unit provides the facility to set "Always Close" operation: this
function, which is programmable only if a Pause Time has already been
programmed, is activated after a power failure; if the gate open condition
is confirmed a closing movement is started automatically, preceded by
5 seconds of preflashing. If you wish to enable the function, proceed as
follows: ensure you have enabled Extended Menu 2 and then use the SEL
key to select blinking LED L7 and press the SET key; at the same time LED
L7 becomes steady on and the operation will be completed. Repeat the
procedure if you wish to restore the previous configuration.
EXTENDED MENU 3
The control unit is factory set to allow direct selection exclusively of the main
menu functions.
If you wish to enable the functions described in Extended Menu 3, proceed
as follows: select blinking LED no. 8 and press SET 3 times. The LED will
start blinking alternately 1 1 1 0 1 1 1 0 1 1 1 0. This means there is a period
of 30 seconds to select the functions in Extended Menu 3 using the SEL and
SET keys and then, after a further 30 seconds, the control unit will revert to
the main menu.
EXTENDED MENU 3
level
L1
1
L2
2
L3
3
L4
4
LED 1 + LED 2 +LED 3 +LED 4
L5
5
LED 1 + LED 2 +LED 3 +LED 4 +LED 5
L6
6
LED 1 + LED 2 +LED 3 +LED 4 +LED 5 + LED 6
L7
7
LED 1 + LED 2 +LED 3 +LED 4 +LED 5 + LED 6 + LED 7
LEV
MENU
LED 1
LED 1 +LED 2
LED 1 +LED 2 +LED 3
3 FLASHES
DECELERATION FORCE ADJUSTMENT:
Operator force during the deceleration stage can be programmed on the
control unit.
You can select one of 6 different power levels as follows; ensure you have
enabled Extended Menu 3; each combination of lit LEDs defines a level as
shown in the above table; in practice, starting from the bottom LED (LED 1)
and proceeding upward, each additional LED corresponds to a higher power
level. Use the SEL key to scroll through the different power levels; for each
selected power level the top LED will blink (for example, selecting level 4,
LED 1 + LED 2 + LED 3 will be steady on, while LED 4 will blink); press SET
to confirm.
Factory setting: level 3 selected.
RESET
If it becomes necessary to reset the control unit to restore the factory
settings, press the SELECT and SET keys together; this will cause all the RED
indicator LEDs to light simultaneously followed immediately by the control unit
switching off.
DIAGNOSTICS
Photocell Test:
The control unit is prearranged for connection of safety devices in compliance
with standard EN 12453 point 5.1.1.6. At each operating cycle a functional
test of the connected photocell is performed. In the case of an open circuit
and/or malfunctioning of the photocell, the control unit does not enable
movement of the gate and visually signals the test failed condition by causing
all the indicator LEDs to blink simultaneously. As soon as correct operation
of the photocell is restored, the control unit is ready for normal use. This
operating mode guarantees failure mode monitoring in compliance with EN
954-1 Category 2.
Commands input test:
IIn correspondence with each low voltage command input, the control unit
is equipped with an indicator LED so that the status of the input can be
checked at a glance.
Operating logic: LED on input closed, LED off input open.
WARRANTY
Fratelli Comunello SpA provides a warranty for 24 months for the correct
functioning of the actuators from the date of manufacture, provided that the
performance specications indicated in the product instruction manuals are
respected. Free of charge repair and replacement of components that are
found to be faulty according to the indisputable judgment of the company's
technical staff shall be guaranteed at the sole discretion of Fratelli Comunello
Spa, and so excluding any claim for damages made by others. Warranty
material shall be returned to Fratelli Comunello S.p.a. headquarters carriage
paid and will then be shipped to the customer carriage unpaid. The material
found to be faulty and returned to Fratelli Comunello S.p.a. shall remain
property of the Seller. Any cost resulting from any work needed to repair
the defect or to replace the material shall be charged to the Buyer. No
compensation shall be allowed for the period of device inactivity. Work under
warranty does not prolong the warranty period. The defect of the product
shall be reported by the Buyer within 8 (eight) days from its discovery or from
the date of delivery of the goods, under penalty of invalidation of the warranty.
Such claim shall be notied in writing.
Warranty does not cover:
Any product defect or damage that may have been incurred during transport;
any defect or damage arising from any fault and/or from neglect, inadequacy
and misuse of the electrical wiring in the Buyer's property; any defect or
damage caused by any repairs carried out by non authorised personnel or
by incorrect use/installation (with reference to this, system maintenance is
recommended every 6 months) or if not original spare parts are used; any
defect caused by chemicals or atmospheric conditions. The warranty does
not cover any cost neither for consumable materials nor for alleged defects
or convenient surveys.
Product Features Fratelli Comunello SpA products are subjected to continue
changes and improvements; their technical features and image may therefore
change without previous notice.
Competent court
Since the contract of sale is conrmed by an Order Conrmation drawn up in
Rosà, any such dispute shall be settled by the laws of Italy and by the court
of Vicenza (VI).
COMUNELLO ®Copyright 2014 - All right reserved
23