Maintenance And Cleaning - Oase BioPress UVC 1000 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

- English -

Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: Isolate the
units and installations (switch off and disconnect from the power supply) before reaching into the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
Note:
● Check and clean the water outlet into the pond at regular intervals.
● Clean the filters at regular intervals (e.g. every four weeks), however, at the latest when cloudy or dirty water from the
water outlet returns to the garden pond.
● Carry out quick cleaning first. Should this prove insufficient, clean the entire unit.
● A blocked filter could lead to leakages.
● Never use chemical cleaning agents.
Quick cleaning
1. Switch off the filter pump
○ Remove hose from the filter outlet by twisting off
the union nut.
○ Remove hose from the filter inlet by twisting off the
union nut and screw on the filter outlet.
2. Screw a dirt drain hose with stepped hose adapter on
the filter inlet.
Switch on the filter pump.
3. Vigorously pull on the cleaning handle and "pump"
several times. In this manner, the foam filters are
mechanically cleaned until the draining water is clear.
Switch off the filter pump.
Remove the dirt drain hose and correctly reconnect
the hoses for normal operation.
BioPress 1600 / 2400
BioPress 1000
6

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Biopress uvc 1600Biopress uvc 2400

Tabla de contenido