Checks And Maintenance; Visual Check; Function Check - INTERSPIRO SPIROSCAPE HP 15 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

7

CHECKS AND MAINTENANCE

7.1
Check that the cylinder is fully charged and that the seal is unbroken.
7.2

Visual check

Check that there has been no mechanical or chemical damage to the following
parts:
Bag, straps and quick-start ring.
l
Air hose, hose couplings and O-rings. Hoses that have lost their flexibility must
l
be replaced.
Outer and inner hood, neck seal and inner mask, including the two snap rings
l
that secure the inner mask and valve.
Sparingly apply talcum powder 460 190 130 (or another talcum powder) to
l
the neck seal at least once a year or as necessary.
Cylinder valve, regulator and pressure gauge.
l
Check that the cylinder has been tested according to national standards.
l

Function check

In addition to the visual check described above, SPIROSCAPE must be tested to
ensure that the apparatus is working properly. To check this, start SPIROSCAPE in
exactly the same way as for normal use and check that the duration time is at least
15 minutes and 20 minutes at the maximum. During the test, the pressure gauge
indicator should drop from full to empty.
When checking and testing is complete, charge the cylinder as described in
chapter 5 and fit the seal as described in chapter 6.
NOTE: IF THERE ARE ANY SIGNS OF DAMAGE OR IF THE APPARATUS DOES NOT WORK PROPERLY, SEND THE
APPARATUS FOR SERVICING OR REPLACE ANY PARTS THAT NEED TO BE REPLACED.
Keep a record of the checking and testing of the SPIROSCAPE. State the date and
the serial number stamped on the cylinder valve.
MONTHLY
ANNUALLY
11

Publicidad

Tabla de contenido
loading