iNSTALLATiON
SPACE
1_
*Finished Width
84-1/2" max.
83-1/2" min.
Finished
Opening
3"
74" From
Floor to
Bottom of
Electrical
3-1/2"
* The finished
cutout
width
must
be 47=1/2"
for 48" models.
Water
and
Electrical
Locations
The opening
must be prepared
with the electrical
and water supply
located
as shown.
Cutout
Depth
The cutout
depth
for the refrigerator
must be at
least 24 inches so that the refrigerator
will be flush
with the adjacent
cabinets,
countertops
or wails.
Additional
Specifications
,, A 115 volt, 60Hz, 15 amp power
supply
is
required.
An individual properly
grounded
branch
circuit
or circuit
breaker
is recommended.
Install a
properly
grounded
3-prong
electrical
receptacle
recessed
into the back wall. Electrical
must be
located
on rear wall as shown.
NOTE:
GFI (ground fault interrupter)
is not
recommended.
,, The refrigerator
should
always
be plugged
into
its own individual
electrical
outlet which has a
voltage
rating that matches
the rating plate.
,, Water line can enter the opening
through
the
floor or rear wall. The water line should
be used
to connect
the cold water line and the water
connection
location.
The line should
be long
enough to extend
to the front of the refrigerator.
Installation
of an easily accessible
shutoff
valve
in the water line is required.
• It is recommended
that you use a mat to
prevent the floor from any possible
damage.
DIMENSIONS
AND
CLEARANCES
25-3/8" Case Depth
**Case Width
84" From
"81-3/4"
Floorto
at Rear
Top Frame
Frameto Frame for 48" Models
Depth Including
Handles 26-7/8"
* Shipping
Height:
front height
may be adjusted
from 83-1/2"
to 84-1/2"
by adjusting
front and
rear leveling
legs a maximum
of 1 inch.
**Case
Width:
must be 47" for 48" models.
Product
Clearances
This refrigerator
is equipped
with a 2-position
door
stop. The factory
set 130 ° door swing
can be
adjusted
to 90 ° if clearance
to adjacent
cabinets
or walls is restricted.
130 ° Door Swing
90 ° Door Swing
I
II:
tt
LI .....
I_D4
23-7/8"
Behind
Frame
C
I-D*!
A
B
C
D
13-7/16"
18-9/16"
28"
4"
Allow minimum
clearances
for Freezer door
(Dimension
A) and Fresh Food door (Dimension
B)
for a full 130 ° door swing and to allow for drawer
removal.
Four inch (4") minimum
clearance
is required
when
door swing
is adjusted
to 90 °. If the 90 ° door stop
position
is used, drawer
access
is maintained,
but
drawer
removal
is restricted.