Compliance With Electrical Standards; Electromagnetic Compatibility - Chauvin Arnoux AmpFlex A100 Manual De Instrucciones

Ocultar thumbs Ver también para AmpFlex A100:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4.5. COMPLIANCE WITH ELECTRICAL STANDARDS

4.5.1 ELECTRICAL SAFETY IN LINE WITH IEC 61010-1 (IEC 61010-031, IEC 61010-2-032)
„ Double insulation
„ Installation category III
„ Operating voltage: 1000 V
„ Pollution level 2

4.5.2 ELECTROMAGNETIC COMPATIBILITY

„ Emissions and immunity in an industrial environment per IEC 61326-1.
- Electrostatic discharge (meets EN 61000-4-2)
8 kV in air - level 3 - class B
4 kV on contact - level 2 - class B
- 10V/m radiated electromagnetic field (in line with EN 61000-4-3)
Class B
- Rapid transients (in line with EN 61000-4-4)
1 kV - level 2 - class B
- Electric shocks (in line with EN 61000-4-5)
6 kV - class B
4.5.3 MECHANICAL PROTECTION
„ Waterproofing (in line with EN 60529)
- Box - protection index IP40
- Flexible probe : protection index IP40
„ Shocks: 100g (in line with IEC 68-2-27)
„ Drop test: 1m (in line with IEC 68-2-32)
„ Vibrations (in line with IEC 68-2-6)
4.5.4 AUTO-EXTINGUISHABILITY RATING
„ Flexible probe: V0 (in line with UL 94)
4.5.5 RESISTANCE TO CHEMICAL PRODUCTS
„ Flexible probe: resistant to oils and aliphatic hydrocarbons
17

Publicidad

Tabla de contenido
loading

Tabla de contenido