C.
Tighten the gas supply fitting and/or appliance conduit
to flare union adaptor on the right side of the pressure
regulator
(refer to Fig. 10) using NO MORE THAN
15ft./Ibs. of torque. Be sure to stabilize
the 1/2"
flare union adapter with an adjustable wrench before
tightening
the gas supply fitting and/or appliance
conduit.
Fig. 10
d.
Install flare union adapter to external manual shut-off
valve (See Fig. 8).
e.
Attach flexible appliance conduit to flare union adaptor
on shut=off valve (See Fig. 8).
f.
Make sure the service shut-off
valve on pressure
regulator
is set to the ON position
(See Fig. 11).
Checking
manifold
gas pressure
Do not use flame to check for gas leaks.
Disconnect the range and its individual shut-off valve from
the gas supply piping system during any pressure testing
of that system at test pressures greater than 14" of water
column pressure (approximately
1/2" psig).
The appliance must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at
test pressures equal to or less than 14" of water column
pressure (approximately
1/2" psig).
If it should be necessary to check the manifold gas
pressure, connect manometer (water gauge) or other
pressure device to the top burner right rear orifice.
Using a
rubber hose with inside diameter of approximately
1/4," hold
tubing down tight over orifice. Turn burner valve on.
For an accurate pressure check have at least two (2) other
top burners burning. Be sure the gas supply (inlet) pressure
is at least one inch above specified range manifold
pressure. The gas supply pressure should never be over
14" water column. When properly adjusted for Natural
Gas the manifold pressure is 4". For LP/Propane Gas the
manifold pressure is 10".
g.
Pressure
regulator
Service
shut-off
valve (shown
in
ON position)
Fig. 11
Check for gas leaks. Turn the gas supply on to the
range and use a liquid leak detector at all joints and
conduits to check for leaks in the system.