24
Foreman Ductable Dual Fuel Indirect-Fired Heater
Ignition Transformer
1. Disconnect ignition transformer wires at terminals #2
& #3 on the terminal block.
2. Loosen mounting torque screws for Ignition trans-
former bracket.
Torque
Screws
3. Slide Ignition transformer bracket up and out.
4. Disconnect igniter cable from ignition transformer.
Ignition
Transformer
Igniter
Cable
5. Remove ignition transformer mounting screws
Motor and Fan Wheel
Fan Wheel Removal
1. Locate and remove three T25 torque screws on
burner blower housing.
Screws
Owner's Manual • Foreman
2. Pull burner blower housing out to expose fan
wheel.
3. Loosen the allen screw (4mm) and remove fan
wheel
4. Inspect fan wheel, clean or replace if neces-
sary.
Burner motor Removal
1. Remove fan wheel, see Fan Wheel Removal
procedure.
2. Remove Air Pressure Switch, see Air Pressure
Switch removal procedure
3. Disconnect motor leads from terminal strip
Motor Lead:
White: #8
Black: #10
Red: #9
Blue: #11
4. Locate and remove two H5 hex head screws.
Motor
Mounting
Screws
5. Remove motor.
Solenoid Valve
Solenoid
Disconnect solenoid wires from burner terminal
block #12 and #11.
Regulator