BSV BS Pool EVOLINK Serie Manual De Usuario página 104

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4.2.1- EVOLINK Warnings
Message:
"CHECK CELL"
"NO ORP PROBE"
"LACK OF SALT"
"TOO
MUCH
SALT"
"NO ORP PROBE"
4.2.2- EVOLINK Alarms
In the following cases, the chlorinator shuts down and the alarm and
acoustic alarm LED is activated (automatic reset once the fault is solved):
*Except pH Alarm
"NO
WATER
FLOW"
"ORP ALARM"
Manual EVOLINK v.5
Causes:
Life cycle of cell is expired.
ORP
probe
is
connected.
Lack of salt in the water.
Incrustations or objects in
the electrolysis cell causing
lack of current.
The electrolysis cell is worn.
Excess salt in the water.
Incrustations or objects in
the electrolysis cell causing
excess current.
The chlorinator is in the
self-cleaning process. The
process takes 5 minutes
Excess
gas
in
electrolysis cell. It may
have occurred because the
pump has shutdown. The
gas is hydrogen gas which
is highly flammable.
Sensor cable of the cell is
incorrectly connected or
broken.
Cell sensor is dirty.
No water flow
ORP probe is dirty, worm
or not connected
Action required:
Clean cell as is explained below
not
Check probe connection.
Add salt to the swimming pool.
Clean the cell.
Replace the electrolysis cell with
a new one.
No action required if excess is
not very significant.
Clean the cell.
None.
the
The piping should be drained to
eliminate gas or accumulated
water. Check the pump.
Check the sensor cable (white
cable)
Clean.
See maintenance.
Check the water system
Check ORP probe conditions, use
pattern liquid
104 / 120

Hide quick links:

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido