3.2.4.2 Technical specification
Measure
Technology
Electronics
Supply
CL measure range
Measure deviation
Operation temperature
Storage temperature
Maximun Operation pressure
pH range
Calibration
Maximum time without CL on water
Maintenance period
3.2.4.3 Installation
Please, carefully follow the recommendations regarding probe installation to
ensure its proper operation:
Manual EVOLINK v.5
TECHNICAL SPECIFICATION
Free chlorine, low pH dependency: Max isocyanuric acid
500mg/L
Membrane. Potentiostatic 3-electrode header
Embedded in the probe. 4-20mA output
12 to 30 VDC (10mA)
0.01 to 10.0 ppm
approx. 3% monthly
0 to 45ºC
0 to 55ºC
0.5 bar. Water hammer effect must be avoided.
4 to 12
Directly on BSV control panel
24h
Water test: Minimum once a week
Header-membrane change: Once a year
Electrolyte change: Every 3-6 months, depending on the
quality of the water
77 / 120