Technical Data
Voltage ...................................................................... 230 V...................... 230 V
Frequency .................................................................. 50 Hz ...................... 50 Hz
Maximum power consumption................................... 750 W..................... 370 W
Maximum fluid temperature....................................... 60°C ....................... 90°C
Approved pumping media.......................................... water, heat transfer medium
Maximum operating pressure ..................................... 5,9 bar .................... 5 bar
Maximum flow rate with
water / heat transfer medium ..................................... 35 / 31 l/min ........... 30 / 27 l/min
Diameter return hose / pressure hose ......................... ½ / ½ inch............... ½ / ½ inch
Tank content.............................................................. 30 l ......................... 30 l
Motor protection class................................................ IP 44 ....................... IP 55
Dimensions (height/width/depth)................................ 760/490/510 mm .... 760/490/510 mm
Weight (empty tank) .................................................. 23,3 kg ................... 21,8 kg
3
Function of the equipment
3.1
Overview
1
2
3
4
3.2
Transportation and unpacking
After unpacking, immediately check the filling unit for completeness and damage.
Immediately report any transit damage to the supplying company.
Dispose of packaging material according to the respective local regulations.
Assembly instruction:
10
filling hose
return hose
tank
pump outlet
ROSOLAR PUMP
5
switch
6
ball valve
7
tank lid
8
filter casing
ENGLISH
ROSOLAR PUMP PLUS
A