With tension different as 400 Volt, the values in Watt and ampere can change.

6.2.2.3 RESET

In some cases it may be necessary to reset the stored data in order to restore the correct
functioning of the OMG electronic card.
To perform this operation, it is necessary to remove the panels and act on the electronic
card inside the electric box while the machine is under voltage. Each operation shall be
carried out very carefully and in conformity with the safety regulations in force.
Follow the instructions below to perform the resetting:
1. Disconnect the machine and remove the electric box from the rear part and remove the
cover.
2. Press keys P1 and P2 on the OMG electronic card SIMULTANEOUSLY and power up
the machine.
3. When the keys are released, three dashes --- shall appear on the display.
This procedure initializes the machine basic programs and makes it possible to recall the
different programs through the keys of the keyboard.
TABLE CONSISTENCY SETTING
W.
1700
1950
2250
2550
2760
3000
A.
5
5,3
5,6
400
5,9
6,2
6,5
V.
NUMERI
140
160
180
200
220
240