Appendix; A Status Display; B Technical Data - Vaillant airMONITOR Instrucciones De Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58

Appendix

A Status display

Status
Test status
Alarm status
Fault status
Operating status
(normal operating
mode)

B Technical data

Height
Depth
Width
Weight
Rated voltage (at 50/60 Hz)
Rated power
Maximum load current
Output voltage at the connection terminal (at 50/60 Hz)
Acoustic signal volume
Permissible ambient temperature
Relative air humidity
Working life
0020234540_02 airMONITOR Installation instructions
Acoustic signal
A repeated acoustic
signal sounds for
2-3 seconds and
then changes to a
continuous acoustic
signal for a further
2-3 seconds.
The acoustic signal
sounds continuously
with regular inter-
ruptions until the
alarm status ends.
The acoustic signal
sounds continuously
without interruption
until the fault status
ends.
The acoustic signal
sounds once after
power is supplied.
LEDs
The red alarm status LED lights up first and then
the entire display goes out for one second until the
yellow fault status LED lights up. If the tests have
been run successfully, the product switches to the
normal operating status (green operating status
LED lights up permanently).
If the CO concentration exceeds the permissible
value, the red alarm status LED lights up. The
power supply to the heat generator is interrupted.
Once the CO concentration falls back below the
permissible value, the power supply is re-estab-
lished and the red alarm status LED goes out.
If the product experiences a malfunction, the yellow
fault status LED lights up first. If the malfunction is
not rectified within the specified time period, the
LED continues to light up. After the malfunction
has been rectified, the yellow fault status LED goes
out.
The green operating status LED flashes first. After
120 seconds, the LED lights up continuously. The
product is in normal operating mode
Appendix
136 mm
45 mm
96 mm
300 g
230 V AC
3 W
1 A
230 V AC
> 85 dB
−10 ... 55 ℃
≤ 95 %
8 years
55

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

0020245425

Tabla de contenido