Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms!
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
anti-pollution function
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
Symbol description
Do not use silicone containing acetic acid!
Adjustment
To adjust the hot water limiter on single lever
mixers, please see page 34. Using a hot
water limiter in connection with a continuous
flow water heater is not recommended.
4
English
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
Assembly see page 32
Dimensions (see page 31)
Flow diagram
(see page 31)
Handspray flow rate
Rate of flow aerator
Spare parts (see page 36)
XXX = Colors
000 = chrome plated
800 = stainless steel optic
Operation (see page 37)
Hansgrohe recommends not to use as
drinking water the first half liter of water
drawn in the morning or after a prolonged
period of non-use.
Cleaning (see page 35)
and enclosed brochure
If the waterflow drops, clean the filter
located between hose and handspray.
Maintenance (see page 35)
The non return valves must be checked
regularly according to DIN EN 1717
in accordance with national or regional
regulations (at least once a year).
Test certificate (see page 40)