�WARNING, DANGER OF ELECTRICAL SHOCK
• In order to avoid electrical shock, valid safety and national regulations regarding excessive contact voltages
must receive utmost attention when working with voltages exceeding 60 VDC, 30 V AC RMS, or 42 V AC peak.
• The respective accident prevention regulations established by the national health & safety board for
electrical systems and equipment must be strictly met at all times.
• Prior to any operation, ensure that the accessory and cable assemblies are in perfect condition.
• The accessory may only be connected to charging equipment as indicated in the technical specification section.
• The accessory may only be used within the operating ranges as specified in the technical specification section.
• The accessory may only be used in dry and clean environments. Dirt and humidity reduce insulation
resistance and may lead to electrical shocks, particularly for high voltages.
• Never use the accessory in precipitation (e.g., dew or rain). In case of condensation due to temperature
jumps, the accessory may not be used.
• Perfect tests and measurements may only be ensured within the temperature range of 0 °C to +40 °C.
• It is not allowed to open this accessory.
• To be used only in combination with test equipment from BEHA-AMPROBE. Please refer to the instruction
manual of this test equipment if it is allowed to connect this accessory.
• If the operator's safety is no longer guaranteed, remove the accessory from service and protect against use.
Safety can no longer be guaranteed if the accessory:
– Show obvious damage
– Do not carry out the desired tests or measurements
– Have been stored for too long under unfavorable conditions
– Have been subjected to mechanical stress during transport
APPROPRIATE USAGE
�WARNING
• The accessory may only be used under conditions and for the purposes for which it was designed.
• If the accessory is modified, operational safety is no longer ensured.
• The accessory may only be opened by an authorized service technician. Before opening the accessory it
must be disconnected from any electrical circuitry.
OPERATION ELEMENTS AND CONNECTORS
2
EVC-13
test cable
1
4
3
5
EVC-20
test cable
1
Test cable input with 7-pole female connector
2
EVC-13 test cable for EV charging station Type 1
with fixed cable and vehicle connector
3
EV connector for charging stations type 1 with
fixed cable and vehicle connector
4
EVC-20 test cable for EV charging station Type 2 with
socket outlet or fixed cable with vehicle connector
5
EV connector for charging stations type 2 with
panel mount socket outlet or fixed cable with
vehicle connector
3