CHARGING PROGRAMS
Settings are made by pressing the MODE-button. A er about two seconds the charger activates the selected program. The selected
program will be restarted next time the charger is connected.
The table explains the diff erent Charging Programs:
Program
Battery Size (Ah)
NORMAL
14–225Ah
AGM
14–225Ah
RECOND
14–225Ah
14
SUPPLY
14–225Ah
WARNING! The spark protection on the battery charger is disabled during SUPPLY program.
Normal battery program
14.4V/7A. Use for WET batteries,
Ca/Ca, MF and for most GEL batteries
AGM battery program 14.7V/7A
Use for AGM batteries.
Recond program 15.8V/1.5A
Use to return energy to the empty WET and Ca/Ca batteries. Recond
your battery once per year and a er deep dischare to maximise lifetime
and capacity. The Recond program adds the Recond step to the normal
battery program. Frequent use of the Recond program may cause
water loss in the batteries and reduce service life of electronics. Contact
your vehicle and battery supplier for advice.
Supply program 13.6V/7A
Use as 12V power supply or use for fl oat maintenance charging when
100% capacity of the battery is required. Supply program activates Float
step without time or voltage limitation.
Explanation
Temp range
+5°C–+50°C
(41ºF–122ºF)
-20°C–+5°C
(-4ºF–41ºF)
-20°C–+50°C
(-4ºF–122ºF)
-20°C–+50°C
(-4ºF–122ºF)