Specifications
Display: LCD, 3-5/6 digits 6000 counts and 3-1/2 digits 1999 counts for Hz
Polarity: Automatic
Update Rate: 5 per second nominal
Operating Conditions:
0 °C to 31 °C (32 °F to 88 °F), 0% to 80% relative humidity
31 °C to 40 °C (88 °F to 104 °F), relative humidity decreasing linearly from 80% to 50%
Pollution degree: 2
Indoor use only
Altitude: Operating below 2000 m (6500 ft)
Storage Temperature: -20 °C to 60 °C, < 80% relative humidity, with batteries removed
Temperature Coefficient:
Nominal: 0.15 x (Accuracy) per °C below 18 °C from 0 °C to 18 °C (32 °F to 88 °F) and above 28 °C
from 28 °C to 40 °C (88 °F to 104 °F) or otherwise specified
Capacitance Mode: 0.25 x (Accuracy) per °C below 18 °C from 0 °C to 18 °C (32 °F to 88 °F) and
above 28 °C from 28 °C to 40 °C (88 °F to 104 °F)
Sensing: True RMS
E.M.C.:
Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3,
EN61000-4-4, , EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11)
In an RF field of 3V/m:
Capacitance function is not specified
Other Function Ranges: Total Accuracy = Specified Accuracy + 200 digits
Performance above 3 V/m is not specified
Safety: Double insulation per UL/IEC/EN61010-1 Ed. 2 & 3, IEC/EN61010-2-030 Ed. 1, CAN/CSA C22.2 No.
61010-1 Ed. 2 & 3, IEC/EN61010-2-032 Ed. 2 and IEC/EN61010-031 Ed. 1.1 to CAT IV 1000V AC & DC
Overload Protections:
Clamp-on Jaws: 2000 A RMS continuous
"+" and COM Terminals (all other functions): 1000 VDC/VAC RMS
Transient Protection: 12.0 kV (1.2/50 μs surge)
Power Supply: Two 1.5 V AA batteries (IEC LR06)
Low Battery: Below approximately 2.4 V
Current Consumption: Typically 14 mA for current modes and 5.2 mA for all other
APO Timing: Idle for 34 minutes
APO Consumption: 10 μA typical
Dimensions: 264 mm x 97 mm x 43 mm (10.4" x 3.8" x 1.7")
Jaw opening and Conductor Diameter: 55 mm max (2.1")

Statement of Conformity

Greenlee Textron Inc. is certified in accordance with ISO 9001 (2000) for our Quality Management
Systems.
The instrument enclosed has been checked and/or calibrated using equipment that is traceable to the
National Institute for Standards and Technology (NIST).