Upper Deflectors Removal; Fireplace Maintenance; Inspection And Maintenance Schedule - Palazzetti Ecomonoblocco MX Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

5.3.3 Upper deflectors removal

1) Pull out the two upper deflectors(A) (Fig. 25).
A

5.4 Fireplace maintenance

The incrustations inside the flue affect the
optimum forced draught. When they reach a
thickness of 5-6 mm, with high temperatures
and sparks, they can ignite with easily imagina-
ble consequences both for the flue and for the
house.
It is therefore recommended to carry
out the cleaning at least once a year
or every 4 tonnes of firewood burned
(as specified in the product standard),
using specialized personnel.
28
5.5 Inspection and maintenance
schedule
A
Grate
Ash drawer/
compartment
Glass
Refractory panels
and fume deflec-
tors (*)
Door seals (*)
Fume evacuation
pipes (*)
(*) By an authorised technical assistance centre.
(**) At least once a year or every 4 tonnes of fuel
burned.
Fig. 25
EVERY
EVERY
IGNITION
YEAR (**)
X
X
X
X
X
X
004778431 - 18/09/2020

Publicidad

Tabla de contenido
loading

Tabla de contenido