Installation instructions
Residual gas: Do not smoke, avoid open flames!
Installation must be conducted by a technician!
Always read the installation instructions prior to installation
and observe them!
Installation options
The output pressure of 30 mbar (yellow type plate) and
50 mbar (orange type plate) at the gas pressure regula-
tion system must correspond with the operating pressure of
the installed equipment.
Please be sure to note the position of the tank fittings before
installation! Truma has 2 variants (90° and 105°) for installation
with 30 mbar.
90°
The 90° variant is available for 50 mbar.
12
105°
The MonoControl CS must be installed in such a way that the
triggering element (A) is always in a vertical position.
It will not be possible to reset a crash sensor that is not
installed vertically to its required original position. This
can lead to spurious activation.
Installation dimensions
A
44
MonoControl CS gas tank installation and
connection
The gas pressure regulation system should be installed so that
the type plate is legible and the green reset button (crash sensor
triggering element reset) is recognisable and easy to access.
A
(in mm)
~ 208