connections of heating circuits 1½"
with flat seals
connections of boiler G 1½"
with flat seals
Bild 1: dimensional sketch
survey and technical data:
nominal diameter
weight
k
-value
VS
dimension A
dimension B
dimension C
max. permiss. operat. temp.
min. permiss. operat. temp.
max. permiss. operat. pressure
Art.-No.
Materials:
Header:
steel tube
union nuts:
Press brass Ms58
flat seals:
EPDM Elastomere
insulation shell:
EPP - with patented groove connection
installation advice:
• Due to three boiler connections, the header may be either
turned or displaced in order to obtain the appropriate po-
sition for the flow of the heating circuit.
• In case of wall assembly the header is fastened via the
threaded connections to the wall-mounted pipework kits.
scope of supply:
• 1 header including union nuts and insulation shells
• 1 cap1 ½"
• seals
3043671_0308
Installation instructions
Header
C
A
125
125
B
125
2 circuits
DN25
6,0 kg
12,0
460 mm
105 mm
500 mm
+ 110 °C
- 20 °C
6 bar
20 12 066
42,5
125
B
125
3 circuits
DN25
9,0 kg
13,0
710 mm
230 mm
750 mm
+ 110 °C
- 20 °C
6 bar
20 12 067
3