Installation
Unit dimensions (fig. 2, page 3)
 I: Top view
 II: Side view
 III: Back view
Unit Capacity
A – Duct Size
B – Base Depth
C – Overall Depth
D – Width
E – Height
8.2
Condensate Drains
WARNING!
!
Do not terminate condensate drain line
– within 0.9 m of any outlet of engine or generator exhaust systems,
– in a compartment housing of an engine or generator,
– in a bilge, unless the drain is connected properly to a sealed
condensate or shower sump pump.
Failure to comply may allow bilge or engine room vapors to mix with the
air conditioners return-air and contaminate living areas which may result
in injury or death.
The following guidelines should be followed during the installation of the
condensate drains:
 Do not route condensate drains to the bilge.
 Run the condensate drain line downward from the unit to a suitable
drain location.
 The condensate drain line should have a trap.
For installation of the condensate drain (fig. 3, page 4):
➤ Remove the aft facing watertight plug from the base pan (4) of the air
conditioning unit.
➤ Slip the solid washer (2) and the liquid-seal washer (3) onto the PVC
fitting (1) in that order.
➤ Connect the PVC fitting (1) through the exposed hole in the base
pan (4) with the locking nut (5).
➤ Securely tighten with two wrenches to provide a proper seal.