Installation
8.9
Unit and Seawater System Installation
8.9.1
Guidelines for Seawater System Installation
A
NOTICE!
If the sea water screen filter is not installed, the pump can be damaged
and the warranty for the pump will be invalidated.
NOTE
I
If the sea water screen filter is not installed, the warranty for the pump will
be invalidated.
The following guidelines should be followed during the installation of the
seawater system:
 The seawater pump must be mounted so that it is always at least
300 mm below the water line.
 The seawater pump may be mounted horizontally or vertically,
however the discharge must always be above the inlet (fig. 5,
page 5).
Item
10
– A: Correct
Steady upward flow from inlet to unit (8), then downward to
outlet (9), hoses double clamped (10).
Thru-hull inlet (1), ball valve (2), hose and strainer (3) should be
sized no smaller than pump inlet.
– B: Incorrect
Hoses must not have kinks, loops or high spots where air can be
trapped.
– C: Incorrect
Pump (4) and strainer (3) must be below water line (7).
– D: Incorrect
Strainer (3) must be below pump (4) and below waterline (7).
24
Description
1
Scoop type thru-hull inlet
2
Ball valve
3
Strainer
4
Seawater pump
5
Air conditioner condensing coil
6
Seawater outlet
7
Water line
8
Inlet flow
9
Outlet flow
Hose clamps, installed in pairs with adjustment ends on opposite
sides
MCS6, MCS12, MSC16